three phase meter test equipment electric meter calibration
Place of Origin: |
Zhejiang, China (Mainland) |
Product Detail
Usage: Auto Electric meter test and calibration
Pow
-
Usage: Auto Electric meter test and calibration
-
Power: Electronic
-
Phase: Three Phase
-
Name: energy meter test equipment, Electric meter test bench
-
Accuracy Class: 0.05%
-
Meter position: 6 / 12 / 24 position
-
Voltage Output: 3×(24V – 300V)
-
Current Output: 3×(1mA – 120A)
-
Operating Temperature: -10°C -- +40°C
-
Adopt ICT to test I-P close link meters
0.05% Accuracy Three Phase Electric Meter Test Bench With ICT
Highlight:
-
Integrated/separated aluminum alloy structure, light and reliable, flexible choices
-
Meter positions can be chosen from 6-24
-
Adopt ICT to test I-P close link meters
-
Auto protections of short circuit of voltage, open circuit of current, and overload
-
Test of neutral current (optional)
-
Auto mark locking increases the efficiency of test
-
Full automatic, semi automatic and manual operation available
-
Supporting bar code input, which increase the efficiency of input
-
Simultaneous test of the meters with same specification, different constants and different classes.
-
Adopt multi-serial port system, realizing the parallel communication of computer and the tested meters( optional)
-
Test of tilt impact (optional)
-
Forward and reverse active energy/ Forward and reverse reactive energy error test
-
Creeping and starting test
-
Standard deviation, 24 hour variation test
-
Timing error test
-
Influencing quantity test of voltage, frequency, harmonic
-
Calibration and verification of constant
-
Register indicating value, register combination error test
-
Powerful computer management system, easy and user-friendly
-
Perfect database management makes the storage, searching, and viewing of the data possible, and the data can be converted and exported in other forms
KE8302 is used for the test of three phase four wire (3P4W) and three phase three wire (3P3W) electrical and mechanical meters, multi-function meters, smart meters, and multi-user meters of electric power company, meter manufacturing company and institutes of metrology, it can also do the test and calibration of single phase energy meters
Main specifications:
|
KE8301-6
|
KE8301-12
|
KE8301-24
|
Number of meter position
|
6
|
12
|
24
|
Accuracy
|
± 0.05%
|
Voltage output
|
Output range (P-N)
|
3×(24V – 300V)
|
Output power of voltage
|
3×100VA
|
3×250VA
|
3×500VA
|
Resolution
|
Better than ± 0.01%
|
Stability
|
Better than ± 0.02% / 150s
|
Load regulation rate
|
Better than ± 0.01%
|
Distortion factor
|
Better than ± 0.3% (linear resistance load)
|
Harmonics output
|
2nd -21st free programmable
|